A Novel Method to Identification Type, Location, and Extent of Transformer Winding Faults Based on FRA and SMOTE-SVM
Loading...
Files
Date
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
DOI
Abstract
Abstract—Currently, the adoption of artificial intelligence is an inevitable necessity in diagnosing
electrical systems failures, also, frequency response analysis FRA is widely used as a tool for diagnostic
mechanical and electrical faults in power transformers, in this paper, a new methodology was proposed based on machine learning and advanced diagnostic technique FRA for detecting the type,
location and severity of transformer fault. The method was applied and test it on three common actual
defects (viz. Axial displacement (AD), Radial displacement (RD), and Short Circuit (SC)) that have
been applied practically to an actual transformer winding at various locations and with different levels.
Initially, the proposed approach is based on the collection and interpretation of the frequency response
analysis (FRA) data of the winding faults to construct a database that can confine all possible cases of
the fault and this has been tried with AD fault. After that, before classification, the problem of imbalance in the databases is addressed. Therefore, a support vector machine (SVM) classifier combined
with SMOTE data preprocessing algorithm has been suggested to solve the imbalance problem.@The
performance of the suggested methodology was evaluated using experimental data collected from the
winding transformer model. Where the results prove the ability of the proposed method to detect the
type, locate and severity of the fault with high accuracy than other methods, which may effectively
contribute to the development of machine learning reliance for the diagnosis of the power transformer
faults.
Description
Citation
Technologie